victronconnect:beta
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
victronconnect:beta [2024-03-09 05:56] – [v6.00beta13] jperez | victronconnect:beta [2024-05-01 21:41] (current) – jperez | ||
---|---|---|---|
Line 10: | Line 10: | ||
(Currently available betas are on top. See further below for official releases.) | (Currently available betas are on top. See further below for official releases.) | ||
- | ==== v6.00beta13 | + | |
- | ** 2024-03-09 ** | + | ==== v6.10beta4 |
+ | ** 2024-05-01 ** | ||
__Download links:__ | __Download links:__ | ||
* iOS: Join TestFlight https:// | * iOS: Join TestFlight https:// | ||
- | * [[https:// | + | * [[https:// |
- | * [[https:// | + | * [[https:// |
- | * [[https:// | + | * [[https:// |
- | * [[https:// | + | * [[https:// |
- | * [[https:// | + | * [[https:// |
Notes: | Notes: | ||
* Android: If you can't open the downloaded file from the downloads list try using a file browser. | * Android: If you can't open the downloaded file from the downloads list try using a file browser. | ||
- | * Settings Lock: When using the settings lock function, use a password that you can easily remember. Recovering a locked product from a forgotten password requires a VE.Direct USB cable or a PUK code for Bluetooth-connected products. | ||
Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue. | Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue. | ||
__Changes__ | __Changes__ | ||
- | * macOS: Fix running VictronConnect on Intel CPU (Universal Application) | ||
- | * Add missing libraries for Linux AppImage build | ||
- | * Make installer remove all the VictronConnect v5.xx files from the installation directory before installing v6.00 | ||
- | * Settings Lock: Fix small UI issues | ||
- | * Small UI improvements | ||
- | VE.Bus inverter/ | + | Energy Meter: |
- | * Fix firmware updating on Windows | + | * Fix Role, Phase Configuration, |
- | Orion XS: | ||
- | * Fix DC input values don't update on remote connection | ||
- | * Fix " | ||
- | Lynx Smart BMS: | + | ==== v6.10beta3 |
- | * Add distributors to the demo product | + | ** 2024-05-01 ** |
- | + | ||
- | ==== v6.00beta12 | + | |
- | ** 2024-02-23 ** | + | |
__Download links:__ | __Download links:__ | ||
- | |||
- | * iOS: Join TestFlight https:// | ||
- | * [[https:// | ||
- | * [[https:// | ||
- | * [[https:// | ||
- | * [[https:// | ||
- | * [[https:// | ||
- | |||
- | Notes: | ||
- | * Android: If you can't open the downloaded file from the downloads list try using a file browser. | ||
- | * Settings Lock: When using the settings lock function, use a password that you can easily remember. Recovering a locked product from a forgotten password requires a VE.Direct USB cable or a PUK code for Bluetooth-connected products. | ||
- | |||
- | Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue. | ||
- | |||
- | __Known issues__ | ||
- | * VictronConnect shows the option to lock the product setting for Orion XS while the product does not support this feature yet. | ||
__Changes__ | __Changes__ | ||
- | + | | |
- | | + | * Correct |
- | * Show product id in the product info page | + | |
- | * Improve information about default PIN code in the devices page onboarding | + | |
- | * Improve information shown when a new file is manually added to the firmware library | + | |
- | * Fix app might freeze when changing PIN code from the default PIN code warning | + | |
- | * Several UI & UX improvements | + | |
- | * Update translations | + | |
- | + | ||
- | VE.Direct Smart Dongle: | + | |
- | * Add firmware update v2.50: | + | |
- | * Add new feature “Settings lock”. This feature will protect critical settings by locking them with a password set via VictronConnect. Non-critical settings can still be changed while the lock is active. | + | |
- | * Several small VE.Smart Networking improvements. | + | |
- | + | ||
- | SmartShunt, BMV-712, SmartSolar and Smart Inverter: | + | |
- | * Add Bluetooth firmware update v2.50: | + | |
- | * Improve Settings lock feature | + | |
- | * Several small VE.Smart Networking improvements | + | |
Multi RS: | Multi RS: | ||
- | * AC Input control: Fix DC condition | + | |
+ | * Add Grid Feed-In configuration (Requires non yet released firmware) | ||
+ | * Add new icons for the grid Disconnection reasons panel | ||
+ | * Update grid disconnection reasons | ||
+ | | ||
+ | * Use correct unit for instant readout today' | ||
+ | |||
+ | MPPT Solar Chargers: | ||
+ | * Add firmware v1.64: | ||
+ | * Internal improvements for 100/30-12V model. | ||
+ | * Improve robustness of SmartSolar 75/10 and 75/15 during shutdown and startup. | ||
+ | * Improve robustness of SmartSolar 100/20 startup under high solar potential. | ||
+ | * Make firmware v3.15 update mandatory for SmartSolar 250/100 rev2 | ||
- | VE.Direct Inverter & SUN inverter: | + | Energy Meter: |
- | * Add firmware v1.35: | + | * Add firmware v1.06: |
- | * Range "ECO mode search interval" | + | * Add LED pulse output |
+ | * Several ethernet related improvements that should help streamlining the firmware update procedure. | ||
+ | * Update the bootloader to v1.04 to benefit from the same ethernet improvements as mentioned above. | ||
EVCS: | EVCS: | ||
- | * Several fixes and improvements | + | * Handle properly |
+ | * Improve robustness of the firmware updater | ||
- | ==== v6.00beta11 | + | ==== v6.10beta2 |
- | ** 2024-02-13 ** | + | ** 2024-04-23 ** |
- | + | ||
- | __Known issues__ | + | |
- | * VictronConnect shows the option to lock the product setting for Orion XS while the product does not support this feature yet. | + | |
__Changes__ | __Changes__ | ||
+ | * Fix minimum Android version required by the Google Play Store to install the app. | ||
+ | * Fix QR Qucick Connect on iOS. | ||
+ | * Add PIN code dialog when connecting to a product through QR Qucick Connect. | ||
- | * Fix VictronConnect do not load on windows systems when updating to v6.00 from v5.xx | + | EVCS: |
- | * Fix VictronConnect do not load on Linux | + | * Add firmware |
- | * Retain alarm notifications until the user has read them. | + | |
- | * Fix product settings pages can appear empty after a reconnection. | + | |
- | * Corrected some VE.Direct inverter models were mistakenly labeled as " | + | |
- | * Various UI fixes and improvements | + | |
- | * Demos: Show Bluetooth Enable/ | + | |
- | * Improve wording related to settings lock | + | |
- | * Fix a bug that might cause firmware | + | |
- | * Fix VE.Smart received data list in some situations do not show the expected items | + | |
- | Orion: | ||
- | * Add firmware v1.03 update: | ||
- | * Add full support to VE.Smart Networking (remote sense). | ||
- | Blue Smart Charger: | + | MPPT chargers: |
- | * Fix Blue Smart Chargers | + | * Fix settings export/ |
- | Multi RS & MPPT RS & Inverter RS: | ||
- | * Add an option to customize the names of MPPT trackers. | ||
- | * Do not show decimals for MPTT tracker power | ||
- | * Multi RS & Inverter RS: | ||
- | * Add "Short circuit" | ||
- | * Add manual control functionality for the built-in relay. | ||
- | | ||
- | BMV: | ||
- | * Add manual control functionality for the built-in relay. | ||
- | Solar Charger: | + | ==== v6.10beta1 |
- | * Add manual control functionality for the built-in relay. | + | ** 2024-04-10 ** |
- | + | ||
- | Phoenix Smart Charger: | + | |
- | * Add manual control functionality for the built-in relay. | + | |
- | + | ||
- | ==== v6.00beta10 | + | |
- | ** 2024-01-26 ** | + | |
- | + | ||
- | __Download links:__ | + | |
- | + | ||
- | * iOS: Join TestFlight https:// | + | |
- | * [[https:// | + | |
- | * [[https:// | + | |
- | * [[https:// | + | |
- | * [[https:// | + | |
- | * [[https:// | + | |
- | | + | |
- | + | ||
- | Notes: | + | |
- | | + | |
- | * Windows: Due to a bug that we'll fix before releasing v6.00, the beta version of VictronConnect might not load correctly on Windows. You see the process in the task manager, but nothing shows on the desktop. Solution: first kill the process (or all of them incase you tried multiple times), then delete c:\program files\victron energy\victronconnect. And now re-install the beta version. | + | |
- | * Settings Lock: When using the settings lock function, use a password that you can easily remember. Recovering a locked product from a forgotten password requires a VE.Direct USB cable or a PUK code for Bluetooth-connected products. | + | |
- | + | ||
- | Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue. | + | |
__Changes__ | __Changes__ | ||
+ | * Fix Android navigation buttons sometimes overlaps the bottom of the app | ||
+ | * Fix some values are partially drawn off screen | ||
+ | * Fix the app will display a shaded overlay when it disconnects from a product while a dialog box is open. | ||
+ | * Return to the devices list instead of the installations list after a remote firmware update | ||
+ | * Fix an issue where a product may be mistakenly added to the "My Products" | ||
+ | * Add initial support for QR Quick connect (feature not available for users yet) | ||
- | Change log | ||
- | * Fix error #R2 when connecting to a remote product. | ||
- | * Various UI fixes and improvements. | ||
- | * Fix notifications drawer can partially hide oldest notification in certain circumstancies. | ||
- | Orion Smart: | + | GX products: |
- | | + | * Fix firmware version |
- | * OrionXS: | + | |
- | | + | |
- | * Add demo product to the demo library | + | |
- | * Add firmware update v1.02. See VictronConnect v5.102 changelog for details. (mandatoy update) | + | |
- | Multi RS, Inverter RS && MPPT RS: | + | MultiPlus |
- | | + | * Fix an issue that may cause settings files to be saved improperly, resulting |
- | * Start the fan for the DCDC circuit earlier. | + | * Add firmware v510 |
- | * Add product settings lock functionality; | + | |
- | * Changes applying to all RS models with a built-in MPPT: | + | |
- | * Improve partial shading mechanism. The old partial shading detection mechanism has been replaced with one that does a periodic full scan. For units with multiple trackers the scans are interleaved. | + | |
- | * Reduce PV under voltage limit from 85V to 65V, which slightly increases the daily energy yield. | + | |
- | * Changes applying to Multi RS only: | + | |
- | | + | |
- | * History logging and VRM reporting: | + | |
- | * Fix bug that caused occasional non-sensible values (negative voltages) | + | |
- | * Fix VRM energy counter reporting in case the inverter is off. | + | |
- | * VE.CAN NMEA2000: | + | |
- | * Fix fast-packet transmissions | + | |
- | * Add a setting to assign custom names to the PV trackers. | + | |
- | * Inverter RS & Multi RS: | + | Energy Meter: |
- | * Improve | + | * Improve |
- | * Add "Off reasons" | + | * Improve firmware updates |
- | * Add descriptions to the operation modes setting | + | |
- | * Add PV inverter yield to the solar history | + | |
Multi RS: | Multi RS: | ||
- | * Show each tracker power in the overview page besides with the total PV power. This information was only available | + | * Add Grid Code support. (Requires new firmware not available |
- | BMV-712 & SmartShunt: | + | ==== v6.05 (Released officially) ==== |
- | * Add firmware v4.16 update: | + | ** 2023-04-25 ** |
- | * Fix: settings lock key& | + | |
- | EVCS: | + | __Download links:__ |
- | * Several UI improvements and fixes | + | |
- | Solar Chargers: | + | * iOS: [[https:// |
- | * Add Bluetooth firmware v2.49: | + | * [[https://play.google.com/ |
- | * Add new feature “Settings lock”. This feature will protect critical settings by locking them with a password set via VictronConnect. Non-critical settings can still be changed while the lock is active. | + | * [[http://updates.victronenergy.com/ |
- | * Several small VE.Smart Networking improvements. | + | * macOS [[https://itunes.apple.com/ |
- | * Add firmware v1.63: | + | * [[https:// |
- | * Add new feature “Settings lock”. This feature will protect critical settings by locking them with a password set via VictronConnect. | + | * |
- | * Add support to relay manual control | + | * Android: If you can't open the downloaded file from the downloads list try using a file browser. |
- | * Add firmware v3.15: | + | |
- | * Add new feature “Settings lock”. This feature will protect critical settings by locking them with a password set via VictronConnect. Non-critical settings can still be changed while the lock is active. | + | |
- | * Add support to resetting error 119 by restoring settings to default | + | |
- | * Reduce change | + | |
- | * Fix " | + | |
- | + | ||
- | Smart Chargers: | + | |
- | * Fix descriptions of errors #14 & #18 | + | |
- | * Add relay manual control mode | + | |
- | + | ||
- | ==== v6.00beta9 ==== | + | |
- | ** 2023-12-13 ** | + | |
__Changes__ | __Changes__ | ||
+ | * Fix Google Play Store reports Android 6 as the minimum Android compatible version instead of Android 8. | ||
+ | * Fix settings files created by VictronConnect v5.xxx do not load on v6.xx | ||
+ | * Fix product id doesn' | ||
- | Change log | + | MPPT chargers: |
- | * Make the BLE/bup update faster and more robust on iOS and macOS | + | * Fix settings export/import buttons are not present |
- | * On Windows, notify that there is a VictronConnect update and provide a manual update option. | + | |
- | * Several UI improvements. | + | |
- | * Various visual artifacts corrected. | + | |
- | * Rename Smart Buck Boost to Orion XS | + | |
- | * Update product | + | |
- | * Settings lock: When logged into a VRM account, product passwords will be stored in VRM. This allows | + | |
- | VE.Bus Inverter/ | + | ==== v6.04 (Released officially) ==== |
- | * Add VE.Bus Inverter/ | + | ** 2024-04-15 ** |
- | * Fix help pop-up are not displayed when clicking on "More info" | + | |
- | Multi RS: | + | __Download links:__ |
- | * Hide SOC discharge limit when " | + | |
- | + | ||
- | ==== v6.00beta8 ==== | + | |
- | ** 2023-09-29 ** | + | |
__Changes__ | __Changes__ | ||
- | Change log | + | * Fix Android navigation buttons sometimes overlaps the bottom of the app |
- | * Prevent non numerical characters on spin box dialogs | + | * Fix some values are partially drawn off screen |
- | * Some buttons colors | + | * Fix the app will display a shaded overlay when it disconnects from a product while a dialog box is open. |
- | * In the settings page, prioritise Bluetooth | + | * Return to the devices list instead of the installations list after a remote |
+ | * Fix an issue where a product may be mistakenly added to the "My Products" | ||
- | HS19: | + | GX products: |
- | * Add a inital support for the HS19 Inverter | + | * Fix firmware version is not shown when connected via local network |
- | BMV-712 | + | MultiPlus |
- | * Add firmware v4.15 | + | * Fix an issue that may cause settings |
- | * Add new feature " | + | * Add firmware |
- | * " | + | |
- | * " | + | |
- | * Add Bluetooth interface | + | |
- | * Add support for " | + | |
- | Multi RS: | ||
- | * Fix overview power readout when unit is in L2 or L3 on 3P systems | ||
- | * Input voltage on demo product | ||
- | * Add support for the generator start/stop control using the built-in relay | ||
- | Energy Meter: | + | ==== v6.03 (Released officially) ==== |
- | * Improve communications | + | ** 2023-03-18 ** |
- | | + | |
- | Smart BuckBoost: | + | __Changes__ |
- | * General improvements | + | |
- | SmartLithium: | + | VE.Bus inverter/ |
- | * Battery cells voltage reads | + | * Fix settings |
- | * Improve Instant Readout when low & high cells are out of range | + | |
- | Inverter RS: | ||
- | * Fix solar current displayed number of decimals | ||
- | |||
- | VE.Bus Smart Dongle: | ||
- | * Add firmware v1.18: | ||
- | * Fix MultiPlus-II 12/ | ||
- | * Add Ve.Bus error code 128 " | ||
- | Lynx Shunt VE.Can | + | ==== v6.02 (Released officially) |
- | * Hide distributors page as it is not supported by hardware. | + | ** 2023-03-16 ** |
- | ==== v6.00beta7 | + | |
- | ** 2023-09-29 ** | + | |
__Changes__ | __Changes__ | ||
- | * Add support for remote firmware updates in the case of multiple VE.Can gateways | + | Multi RS: |
- | | + | |
- | Victron Energy Meter: (Backported to v5.98) | + | GlobaLink520: |
- | * Several connection fixes and improvements | + | * Fix update feed setting |
- | * Fix remote firmware updates when energy meter is connected to GX via Ethernet (requires Venus 3.20~7) | + | |
- | + | ||
- | Lynx SmartBMS D: | + | |
- | * Add initial support | + | |
- | + | ||
- | smallBMS Smart: | + | |
- | * Add initial support | + | |
- | ==== v6.00beta6 | + | ==== v6.01 (Released officially) |
- | ** 2023-09-22 ** | + | ** 2023-03-14 ** |
__Changes__ | __Changes__ | ||
- | * Fix .bup firmware updating on iOS 17 | + | Android: |
- | * Fix firmware from user library | + | * Fix Application Not Responding(ANR) seen on certain conbination of hardware/ |
- | Phoenix & Sun Inverters: | + | ==== v6.00 (Released officially) |
- | * Notify setting changed for new ECO interval | + | ** 2023-03-13 ** |
- | + | ||
- | ==== v6.00beta5 | + | |
- | ** 2023-09-19 ** | + | |
__Changes__ | __Changes__ | ||
- | | + | **New Feature: Settings Lock** |
+ | * **Installer-Enabled Settings Lock:** Now, installers can set a password to lock settings, ensuring that end-users cannot accidentally modify critical configurations on their systems. | ||
+ | * **Easy Unlocking: | ||
+ | * When you log into VRM, the product passwords are securely stored in VRM and synchronized across all your devices—phones and computers—where you are logged into your VRM account. | ||
+ | * **Firmware Update Required:** Settings Lock feature requires compatible firmware. Firmware updates for the products supporting this feature are included in this VictronConnect version. | ||
+ | |||
+ | **Qt Framework Upgrade:** Marks a significant milestone as we transition from Qt 5 to Qt 6. This update brings numerous improvements and advantages that enhance your user experience and set the stage for new features in the future. | ||
- | Victron Energy Meter: (Backported to v5.98) | + | Minimum OS version requirements: |
- | * Fix live data is not displayed | + | * Android: |
- | * Fix firmware updating. Remote updating of an Energy | + | * Android 8 or higher: (previously Android 5) |
+ | * For older versions VictronConnect v5.106 is available in [[https:// | ||
+ | * iOS: | ||
+ | * iOS 14 or higher (previously iOS 12) | ||
- | ==== v6.00beta4 ==== | + | * Microsoft Windows: |
- | ** 2023-09-19 ** | + | * Windows 10 or higher. (previously Windows 7) |
+ | * For older versions VictronConnect v5.106 is available in [[https:// | ||
- | __Changes__ | + | * macOS: |
+ | * macOS Big Sur (11) or newer (previously macOS Sierra (10.12)) | ||
+ | |||
+ | |||
+ | * In the settings page, prioritise Bluetooth firmware update available notification. | ||
+ | * On Windows, notify that there is a VictronConnect update and provide a manual update option. | ||
+ | * Fix notifications drawer can partially hide oldest notification in certain circumstancies. | ||
+ | * Retain alarm notifications until the user has read them. | ||
+ | * Demos: Show Bluetooth Enable/ | ||
+ | * Improve information shown when a new file is manually added to the firmware library | ||
+ | * Several UI/UX improvements | ||
+ | * Various internal improvements | ||
- | * Fix .bup firmware updating on iOS 17 | ||
- | * Fix stored trends are not working at all. Issue added in v6.00beta1 | ||
- | * Settings Lock: Various fixes and UX/UI improvements | ||
- | Victron Energy Meter: | + | Multi RS, Inverter RS && MPPT RS: |
- | * Add support for VM-3P75CT model: (Backported to v5.98) | + | * Add firmware v1.16: |
- | * The connection is established using UDP, so the device | + | * Check [[https:// |
- | * Connection via VRM is also possible, whether | + | |
- | * Currently remote firmware update is only possible when the Energy Meter is connected via VE.Can | + | |
+ | * Improve alarms behaviour | ||
+ | * Add “Off reasons” button | ||
+ | * Add descriptions | ||
+ | * Add PV inverter yield to the solar history | ||
+ | * Add "Short circuit" | ||
+ | * Add manual control functionality for the built-in relay. | ||
+ | * Make system configuration available in demo products | ||
+ | * Show each tracker power in the overview page besides with the total PV power. This information was only available in the status page. | ||
- | Multi RS: | + | * Multi RS: |
- | * Add energy meter support. (Requires beta firmware) | + | * Fix overview power readout when unit is in L2 or L3 on 3P systems |
+ | * Input voltage on demo product | ||
+ | | ||
+ | * AC Input control: Fix DC condition connection delay | ||
- | Phoenix & Sun Inverters: | + | EV Charging Station: |
- | * Set max ECO search interval to 1h | + | * Add all set of settings that are currently available via the web interface. |
- | SmartShunt / BMV-712: | + | BMV-712, BMV-710h & SmartShunt: |
- | * Add Bluetooth | + | * Add firmware |
- | * Fix for occasional erroneous battery temperature broadcasts causing Smart Solars | + | * Fix: settings lock key& |
- | * Add support for VE.Smart Networking for new IP65 Rev2 Smartshunts. | + | |
- | * Fix for SOC trend scaling error. In some situations a wrong SOC value could end up in the stored trend for SOC (only the stored trend; the SOC value itself was not affected). | + | |
+ | * Add manual control functionality | ||
+ | VE.Direct Smart Dongle: | ||
+ | * Add firmware update v2.50: | ||
+ | * Add new feature “Settings lock”. | ||
+ | * Several small VE.Smart Networking improvements. | ||
- | ==== v6.00beta3 ==== | + | SmartShunt, BMV-712, SmartSolar and Smart Inverter: |
- | ** 2023-09-12 ** | + | * Add Bluetooth firmware update v2.50: |
+ | * Improve Settings lock feature | ||
+ | | ||
- | * Android: If you can't open the downloaded file from the downloads list try using a file browser. | + | Smart Chargers: |
+ | * Fix descriptions of errors #14 & #18 | ||
+ | * Add relay manual control mode | ||
+ | * Add manual control functionality for the built-in relay. (Only for models with buitl-in relay) | ||
- | Please report bugs and give feedback | + | Solar Chargers: |
+ | * Add Bluetooth firmware v2.49: | ||
+ | * Add new feature “Settings lock”. | ||
+ | * Several small VE.Smart Networking improvements. | ||
+ | * Add firmware v1.63: | ||
+ | * Add new feature “Settings lock”. | ||
+ | * Add support | ||
+ | * Add firmware v3.15: | ||
+ | * Add new feature “Settings lock”. | ||
+ | * Add support to resetting error 119 by restoring settings | ||
+ | * Reduce change of mis triggering PV Input shutdown errors | ||
+ | * Fix “Lifetime total” & “Since reset” yield does not show in some screen configurations. | ||
+ | * Add manual control functionality for the built-in relay. | ||
- | __Changes__ | + | Orion Smart: |
+ | * Add “Off reasons” button and notifications. This shows an explanation of why the product is in off state.3 | ||
- | | + | VE.Direct Inverter & SUN inverter: |
+ | | ||
+ | * Range "ECO mode search interval" | ||
- | VE.Bus Inverter/ | + | Lynx Smart BMS: |
- | * Add new MultiPlus/ | + | * Add distributors |
- | * Improvements | + | |
- | * Fix reported name for Quattro 12/ | + | |
- | + | Orion XS: | |
- | SmartSolar: | + | * Fix DC input values don't update on remote connection |
- | * Fix settings import/ | + | * Fix " |
VE.Bus Smart Dongle: | VE.Bus Smart Dongle: | ||
- | * Fix firmware | + | * Add firmware |
- | * Add VE.Bus Smart Dongle firmware v1.17 | + | * Fixed MultiPlus-II 12/ |
- | * Improve sustain state reporting | + | |
+ | ==== v5.107 (Released officially) ==== | ||
+ | 2024-03-16 | ||
- | Inverter/ | + | __Changes__ |
- | * Make system configuration available in demo products | + | |
- | ==== v6.00beta2 ==== | + | Windows only: |
- | ** 2023-09-07 ** | + | * Do not update to v6.xx when running on Windows 10 32-bit |
- | __Changes__ | ||
- | * Fix Bluetooth scanning on Android > 11 | + | ==== v5.106 (Released officially) ==== |
- | ==== v6.00beta1 ==== | + | 2024-03-13 |
- | ** 2023-09-02 ** | + | |
__Changes__ | __Changes__ | ||
- | * **Qt Framework Upgrade:** Marks a significant milestone as we transition from Qt 5 to Qt 6. This update brings numerous improvements and advantages that enhance your user experience and set the stage for new features in the future. | + | Windows only: |
- | * Improve Bluetooth connection on Android phones using UNISOC SoC | + | * Prevent auto updating |
- | * Various improvements | + | |
- | + | ||
- | ** New Feature: Settings Lock ** | + | |
- | + | ||
- | * **Installer-Enabled Settings Lock:** Now, installers can set a password | + | |
- | + | ||
- | * **Easy Unlocking: | + | |
- | * **Firmware Update Required:** Settings Lock feature requires | + | |
- | + | ||
- | Smart BuckBoost: | + | |
- | * Include initial support (Backported to v5.98) | + | |
- | + | ||
- | Phoenix Inverter: | + | |
- | * Prepare for extended ECO search interval that will be included in upconming firmware version. | + | |
- | + | ||
- | EV Charging Station: | + | |
- | * Add all set of settings that are currently available via the web interface. | + | |
==== v5.105 (Released officially) ==== | ==== v5.105 (Released officially) ==== | ||
** 2024-02-21 ** | ** 2024-02-21 ** | ||
- | |||
- | __Download links:__ | ||
- | |||
- | * iOS: [[https:// | ||
- | * [[https:// | ||
- | * [[http:// | ||
- | * macOS [[https:// | ||
- | * [[https:// | ||
- | |||
- | * Android: If you can't open the downloaded file from the downloads list try using a file browser. | ||
__Changes__ | __Changes__ | ||
Line 696: | Line 581: | ||
* Disallowed product release in Test mode, when HW rev2 is not set | * Disallowed product release in Test mode, when HW rev2 is not set | ||
* Set minimum App version to v1.09 for HW rev2 products | * Set minimum App version to v1.09 for HW rev2 products | ||
- | |||
- | MultiRS: | ||
- | * Make experimental ESS settings available when running beta firmware | ||
==== v5.91 (Released officially) ==== | ==== v5.91 (Released officially) ==== | ||
Line 770: | Line 652: | ||
Multi RS: | Multi RS: | ||
* Improve and add extra information to ESS mode selection | * Improve and add extra information to ESS mode selection | ||
- | * Add new ESS modes (only for beta FW) | ||
* Hide “Monitor PE to Neutral voltage” setting for models not supporting it | * Hide “Monitor PE to Neutral voltage” setting for models not supporting it | ||
* Add new aux input modes | * Add new aux input modes | ||
Line 983: | Line 864: | ||
* Add " | * Add " | ||
* Split the " | * Split the " | ||
- | * Add AC input control settings. (Requires new beta firmware) | ||
* Fix inconsistency on how frequency is shown for AC Out 2 | * Fix inconsistency on how frequency is shown for AC Out 2 | ||
* Use correct AC out power when AC IN relay is open | * Use correct AC out power when AC IN relay is open | ||
Line 4086: | Line 3966: | ||
===== DISQUS ===== | ===== DISQUS ===== | ||
~~DISQUS~~ | ~~DISQUS~~ | ||
+ |
victronconnect/beta.1709960188.txt.gz · Last modified: 2024-03-09 05:56 by jperez